Errors
If an error is detected, “Status: Error” will be displayed
on the Version, Status screen (control panel) or on the
Operations page (browser). To learn the cause of the
error, press NEXT (if using control panel) to proceed to
the Error screen or click on Error (if using browser). You
must acknowledge the error to clear the error register.
Click + (control panel Error screen) or Acknowledge
(browser) to clear the error. If the error remains, power
cycle the unit and attempt to clear the error register a
second time. If a system overheat or an amp overheat
occurs, ensure that the unit is housed below its maxi-
mum operating temperature. If an amp short occurs,
check recently-installed cabling for a short. If the error
persists, contact your dealer.
• To protect circuitry, if an error results in a Zone
shutdown, the system will wait five (5) minutes
before attempting to clear the fault. If the system
is able to clear the fault, the Zone will be brought
back up automatically.
• During these five (5) minutes the installer should
check recent cable additions for shorts.
• If the fault does not clear on its own after five (5)
minutes, power cycle the unit and attempt to clear
the error register a second time. If the fault remains,
contact your dealer.
• If the error condition is gone, the zone will come
back up (will generate sound). The “Status: Error”
Indicator will display until the error indication is
acknowledged. You must still clear the fault register
as described in first paragraph above.
Error Register: [6 hexadecimal digits]:
Errors are shown as a six (6) digit alphanumeric code.
(EXAMPLE: “Status: 003000”) The position of the digit
identies the specic component aected (e.g. the
entire system or a single zone).
SYSTEM
STATUS
Z5 STATUS
Z4 STATUS
Z3 STATUS
Z2 STATUS
Z1 STATUS
# # # # # #
0 0 3 0 0 0
EXAMPLE*:
*This example indicates a fault in Zone 4.